HOME 〉 PRODUCTS 〉 Current Transformer 〉 Model 6463A Error Compensation Current Transformer (Standard Current Transformer)

Model 6463A Error Compensation Current Transformer (Standard Current Transformer)

Model 6463A Error Compensation Current Transformer (Standard Current Transformer)

Model 6463A can output from primary current of 5 A to secondary current with in-phase error ±20 ppm (at 50Hz, 0Ω load) and quadrature phase error 20μrad (at 50Hz, 0Ω load). Therefore it can be used as a standard current transformer for various calibration operation. Combined with model 6040A and 6462A wider range of currents become available.

Features

  • Structure of the transformer is two-stage transformer with a compensation coil. Therefore secondary current is highly accurate.
  • Secondary output currents are 1/100, 1/250, 1/500 and 1/1000 of a primary current.
  • As the transformer part is molded and the whole unit contained in an aluminum-alloy system case, the devise is durable for a long term use and safely maintains its performance.

Specifications

Item/ModelTYPE 6463A
Primary Current Rating5 A (max. 10A)
Secondary Current Rating5 mA,10 mA,20 mA,50 mA
Frequency50 Hz to 400 Hz
In-Phase Error20 ppm (at 50Hz, 0Ω load)
30 ppm (at 400Hz, 0Ω load)
Quadrature Phase Error20μrad (at 50Hz, 0Ω load)
60μrad (at 400Hz, 0Ω load)
Rated Load0.025 VA (at 50 mA Range)
Secondary Short, Primary Input Equivalent AC ResistanceLess than 1Ω
Power Supply100 Vac、50/60 Hz、1 A
Size (WxDxH) mm450×430×130
Weight Approx. 7 kg
  • Specifications are subject to change without notice due to improvement
  • SunJEM will design products to meet your individual requirements.
    Please feel free to consult with us for products other than ready-made ones.